Skip to content
DPSIM Changelog
1.1.0.2 – September 7, 2026
- Added Layout toolbar commands to add or remove routing nodes on a selected stream.
- Stream node commands now follow stream selection and canvas lock state automatically.
1.1.0.1 – August 27, 2026
- Expanded the Stream Inspector with direct stream selection and separate simulated and experimental data views.
- Added reference-stream comparisons for mass recovery, component recovery and D80 reduction ratio.
- Added PSD and component curves from multiple streams to the same chart, with individual colors, line styles, widths and markers.
- Added chart controls for copying, exporting, configuring and locking the current stream selection.
- Improved chart behavior when navigating between individual streams and equipment inlet and outlet streams.
- Improved the Stream Inspector layout, default size and panel proportions while preserving user-customized layouts.
- Corrected inconsistent P80/D80 values and cumulative passing calculations in stream displays.
- Improved stream curve labels so their equipment and connection are easier to identify.
- Added toolbar shortcuts to the online User Guide and Models Reference.
1.1.0.0 – August 25, 2026
- Added Bimodal Rosin-Rammler Comminution for fitting product size distributions with two particle populations, including global and component-specific curves with closed size and component mass balances.
- Added Rosin-Rammler Product Comminution for defining a mass-closed product PSD from D80, curve slope and a fine-size passing plateau, globally or by component.
- Prevented the Rosin-Rammler comminution models from producing a product coarser than their feed; incompatible targets are now limited and reported.
- Added Flow Rate Transition, a Feed model for representing an intentional change in solids and water throughput between steady-state sections while preserving feed PSD and component composition.
- Added Product Assay Separation, which calculates mass-closed component recoveries from concentrate and tail grade targets with anchor, reconciliation and fallback modes.
- Added Target Product P80 Partition, which calculates a two-product partition curve from a requested coarse- or fines-product P80 for the global PSD or individual components.
- Added dedicated, component-aware setup windows for Product Assay Separation, Target Product P80 Partition and both Rosin-Rammler comminution models.
- Expanded stream flyout configuration with arbitrary Dx and percent-passing fields, plus mass and component recovery relative to a selected reference stream.
- Added a complete stream-details window opened by double-clicking a stream, with stream data, size distribution, component-by-size data and the PSD chart in one view.
- Corrected component passing curves in stream charts so the finest size class is included consistently with the global PSD.
1.0.0.4 – August 22, 2026
- Added Component Recovery Separation, Three-Parameter Recovery Separation and Basic Separation to the Concentration > Separators model menu.
- Renamed the Density Regulator model in the interface to Pulp Dilution Control. Existing project files remain compatible.
- Renamed Equipment Splitter in the interface to Stream Splitter.
- Added periodic online update verification. DPSIM Static Module can remain offline for up to seven days after a successful check.
1.0.0.3 – August 18, 2026
- Corrected an error that could occur when closing DPSIM after installation under Program Files.
- User preferences are now stored in the Windows user profile, where they can be saved without administrator access.
- Existing preferences stored beside the application remain compatible and are migrated when settings are next saved.
1.0.0.2 – August 13, 2026
- Expanded the End User License Agreement to cover licensing, engineering responsibilities, project data, privacy, updates, support, technical validity and applicable legal protections.
- Synchronized the terms displayed by the installer, the application and the DPSIM website.
- Existing installations will request acceptance of the updated terms before continuing.
1.0.0.1 – July 20, 2026
- Improved steady-state simulation performance, especially for repeated flowsheet iterations.
- Changed Results Sheet to show streams as columns by default and added a transpose option.
- Improved water-addition visibility when a Density Regulator is connected to a Water Feed.
- Corrected stream-data editing and refresh behavior in the right-side inspection panel.
- Improved automatic error reports so exception details can be reviewed and sent with a problem report.
- Simplified the Static Module interface to keep the public release focused on steady-state simulation and results reporting.
- Corrected the startup example flowsheet layout and several interface stability issues.
1.0.0.0 – Initial Public Release
- Build and edit steady-state mineral processing flowsheets.
- Configure documented unit-operation models.
- Run static simulations and review stream and equipment results.
- Export result sheets and engineering reports.
- Install DPSIM per user without administrator elevation in the standard configuration.
- Receive automatic DPSIM updates and see a What's New summary after an update.