Summary
Impose an entered product particle size distribution while passing the feed’s dry-solids and water flow rates through to the product.
Ribbon Flowsheet → Auxiliary → Output constraints
Model key DPSIM.Auxiliary.FixedPSDOutput
Ports
| Port | Direction | Meaning |
|---|---|---|
| Feed | Input | Combined inlet material. |
| Product | Output | The same dry-solids and water flow rates, with an imposed PSD. |
Configuration in DPSIM
- Connect Feed and Product. Double-click the unit or choose Edit in the equipment Inspector to open Fixed PSD Output.
- Enter Retained (%) beside the applicable apertures. Check that the running total leaves a physically meaningful pan fraction and review the cumulative passing preview.
- Choose the product composition mode. If using experimental product grades by size, select Product and enter the matrix under Show stream input data → Components.
- Apply, run the flowsheet and inspect Product with Show stream simulated data.

Parameters and units
| Input | Units or options | Initial value or basis | Use |
|---|---|---|---|
| Product retained mass by class | % of product dry solids | Entered on the project sieves | Set the retained percentage at each editable size. The top row is fixed at zero. The pan is calculated as 100 minus the sum of editable rows. |
| Product composition | Preserve bulk feed grades (1) or Use experimental product grades by size (0) | 1 | Mode 1 applies feed-average grade to every class. Mode 0 takes the component-by-size matrix from product stream input data. |
| Product grades by size | % of class dry solids | From product stream input data | Required in mode 0. Enter a complete dry-solids composition for each occupied class. |
Calculation and assumptions
Imposed size fractions
Let rᵢ be the retained fraction for size class i, Fₛ the feed dry-solids mass rate and Fw the feed water mass rate. Product solids and water pass through at the feed rates. The imposed PSD sets the dry mass in each size interval.
S_product = Fₛ W_product = Fw Sᵢ = Fₛ rᵢ Σᵢ rᵢ = 1
Composition assignment
For component j, mode 1 uses the overall dry-solids grade gⱼ of the feed in every size interval. Mode 0 uses the input product grade gᵢⱼ in each class. Sum the class contributions to obtain the product component rate.
Component rate, mode 1: Σᵢ Fₛ rᵢ gⱼ = Fₛ gⱼ Component rate, mode 0: Σᵢ Fₛ rᵢ gᵢⱼ
Application
Use this block to carry a measured downstream PSD into a flowsheet or impose a specification for a sensitivity case. Use a calibrated model when the study needs product size to respond to upstream size, equipment settings or energy.
Calculated results
| Result | Units or basis | How to interpret it |
|---|---|---|
| Dry-solids and water flow | t/h | In Product → Stream, compare both values with Feed. |
| Retained and passing | % of product dry solids | In Product → Size Distribution, compare passing against the intended sieve basis. |
| Component rates and grades | t/h and % of dry solids | In Product → Components, review the grade mode and any change in component mass rates. |
Worked verification example
Use 100 dry t/h and 25 t/h of water. Set size boundaries at 400, 200, 100 and 50 µm. Enter retained percentages of 0, 25, 30 and 35 above the pan. Use a 60% bulk grade for the component of interest. These inputs describe a synthetic balance check.
| Check | Calculation or basis | Expected value |
|---|---|---|
| Pan fraction | 100 − 25 − 30 − 35 | 10% |
| Passing 100 µm | 35% in the 50–100 µm interval + 10% pan | 45% |
| Component in product, mode 1 | 100 × 0.60 | 60 t/h |
| Component in product, mode 0 | Use product grades of 70%, 60%, 50% and 40% for the four populated classes | 57 t/h |
| Product stream flow | Feed flows carried through in both modes | 100 dry t/h and 25 t/h water |
Diagnostics and calibration
| What you see | What to check |
|---|---|
| Pan is unexpectedly large | Check the cumulative passing data were converted to retained percentages before entering the table. |
| Bulk grade changes after editing the PSD | Check the composition mode and the mass-weighted product grades by size. Mode 0 can deliberately change component rates. |
| Product PSD looks unchanged | Apply the editor and run the flowsheet. Compare the simulated product tab with the entered product PSD. |