Summary
Calculate a hydrocyclone’s pressure drop, corrected cut size and split to underflow and overflow from slurry feed, geometry and calibrated correlations.
Ribbon Flowsheet → Classification → Hydrocyclones
Model key DPSIM.Classification.Nageswararao
Ports
| Port | Direction | Meaning |
|---|---|---|
| Feed | Input | Slurry with a size distribution and positive slurry density. |
| Underflow | Output | Water and solids assigned to the coarse-product side of the cyclone. |
| Overflow | Output | Complementary water and size-by-component mass. |
Configuration in DPSIM
- Open the cyclone input editor. Under Operating Cyclones, enter the count and geometry for the units currently in service.
- Under Calibration, select Published (2004) for a new calibration, or preserve the Legacy basis for a case calibrated with it. Apply operating data and run the circuit.
- Compare pressure against a measured per-cyclone operating point. Then check water split and corrected size before fitting curve sharpness or the fish-hook.
- In Underflow split, compare the actual dry-solids partition with the corrected curve. Match the size unit and identify underflow and overflow before comparing curves.

Parameters and units
| Input | Units or options | Initial value or basis | Use |
|---|---|---|---|
| Operating cyclones | Whole number from 1 to 1,000 | 1 | Divide combined feed slurry flow uniformly by this count. |
| Cyclone diameter Dc | mm | 254 | Use the internal body diameter. Divide by 1,000 for the capacity and cut-size equations. |
| Equivalent feed inlet diameter Di | mm | 63.5 | Use the equivalent diameter for the actual inlet. It must be smaller than Dc. |
| Vortex finder diameter Do | mm | 76.2 | Use the internal overflow opening. It must be smaller than Dc. |
| Spigot diameter Du | mm | 38.1 | Use the internal underflow opening. It must be smaller than Dc. |
| Cylindrical section length Lc | mm | 254 | Use the cylindrical section length. |
| Full cone angle | Degrees | 20 | Use the included angle. |
| Model formulation | 0 Legacy or 1 Published (2004) | 1 for new equipment | Old projects with an absent formulation use Legacy. Select a supported formulation when opening a project with a retired value. |
| Corrected cut size calibration KD0 | Coefficient on the correlation basis | 0.000080 | Adjust against corrected d50 data. |
| Capacity calibration KQ0 | Coefficient on the m³/h basis | 440 | Adjust against measured pressure and flow per cyclone. |
| Water recovery calibration KW1 | Coefficient on the selected formulation basis | 7.30 | Adjust against measured water recovery to underflow. |
| Slurry volume recovery calibration KV1 | Coefficient on the selected formulation basis | 9 | Calibrates the independent volume-recovery diagnostic. |
| Calibrated partition sharpness α | Dimensionless | 1.4 | Fit the corrected partition’s steepness. |
| Partition fish-hook coefficient β | Dimensionless | 0 | Set zero for the base Whiten curve. A positive value enables the fish-hook correction. |
Calculation and assumptions
Notation and feed basis
Qc is feed slurry flow per cyclone in m³/h. ρp is pulp specific gravity, Cv is feed solids volume fraction, θ is full cone angle in degrees and g = 9.80665 m/s². The equation uses Dc in m, with ratios i = Di/Dc, o = Do/Dc, u = Du/Dc and l = Lc/Dc. The feed needs a liquid phase and positive density.
Pressure and corrected cut size
B is the geometry-adjusted capacity term, ΔP is in kPa and G is the pressure group. H is the scaled Steinour factor. KD0 produces a cut size on the metre-based correlation and DPSIM converts the result to µm.
B = KQ0 Dc^1.90 o^0.68 i^0.45 l^0.20 θ^−0.10 ΔP = ρp (Qc / B)² G = ΔP / (ρp g Dc) H = 10^(1.82 Cv) / [8.05 (1 − Cv)²] d50c = 10⁶ KD0 Dc^0.35 o^0.52 u^−0.50 i^0.20 l^0.20 θ^0.15 G^−0.22 H^0.93
Water and slurry volume correlations
For Published, use a = −0.50 and b = −0.25. For Legacy, use a = +0.50 and b = +0.25. The water split uses Rw bounded to [0, 1]. Rv is reported independently, alongside the actual slurry volume recovery from the simulated product streams.
Rw = KW1 o^−1.19 u^2.40 i^a l^0.22 θ^−0.24 G^−0.53 H^0.27 Rv = KV1 o^−0.94 u^1.83 i^b l^0.22 θ^−0.24 G^−0.31
Partition by size
At representative particle size d, evaluate the reduced overflow fraction using x = β* d/d50c. With β = 0, β* is 1. With a fish-hook, DPSIM finds the descending crossing O(β*) = 0.5. The model evaluates geometric-mean sizes for closed sieve classes and half the finest physical aperture for a zero-aperture pan.
O(x) = (1 + βx)(exp(α) − 1) / [exp(αx) + exp(α) − 2] Actual underflow fraction = 1 − clamp[(1 − Rw,bounded) × O(x), 0, 1]
Balances and calibration
Apply the same size partition to the dry mass of each component within a size class. The remaining mass and water go to overflow. At d50c, the corrected underflow partition is 50%. The actual curve includes water bypass and is above 50% at this size when the bypass is positive.

Calculated results
| Result | Units or basis | How to interpret it |
|---|---|---|
| Feed slurry flow per cyclone and feed pressure | m³/h and kPa | Compare with the observed cyclone count, feed flow and pressure. |
| Corrected cut and partition sharpness | µm and dimensionless | Use corrected partition data when interpreting d50c and α. |
| Water and solids recovery to underflow | % of the corresponding feed mass | Check separately against the survey. |
| Pressure group and scaled Steinour correction | Dimensionless | Use to reproduce the correlations from recorded conditions. |
| Raw correlated water recovery | % | Compare with bounded water recovery when the model reports bounding. |
| Correlated and simulated slurry-volume recovery | % | The first is a diagnostic correlation. The second is obtained from the underflow and feed slurry flows. |
Worked verification example
Use one cyclone with the defaults above, 25 m³/h slurry feed and solids specific gravity 3.0 at 15% solids by volume. With water specific gravity 1.0, pulp specific gravity is 1.30. Enter 11.25 dry t/h and 21.25 t/h water to reproduce the slurry feed. Use β = 0. Keep the same geometry and coefficients in both formulations to isolate the change of basis.
| Check | Calculation or basis | Expected value |
|---|---|---|
| Feed pressure | Same capacity correlation in both formulations | 24.9876 kPa |
| Dimensionless pressure group and scaled Steinour factor | Use Cv = 0.15 | 7.7166 and 0.32238 |
| Corrected cut size | Same cut-size correlation in both formulations | 18.0771 µm |
| Water recovery to underflow | Published compared with Legacy | 7.8320% compared with 1.9580% |
| Independent slurry volume recovery | Published compared with Legacy | 31.7074% compared with 15.8537% |
| Actual underflow partition at d50c | (1 + bounded Rw) / 2 | 53.9160% Published and 50.9790% Legacy |

Diagnostics and calibration
| What you see | What to check |
|---|---|
| Corrected and actual curves give different cuts | Identify which curve was measured and check liquid bypass before fitting d50c. |
| Pressure is inconsistent | Check cyclone count, slurry volumetric flow, dimensions in mm and whether the survey reports pressure per cyclone. |
| Water split is bounded or volume diagnostic exceeds 100% | Check geometry, solids concentration, coefficient basis and formulation. Review the measured split before adopting the result. |
| A saved case rejects its formulation | Choose Legacy or Published explicitly. Recheck calibration after changing the formulation. |
