Summary
Check a specified underflow solids volume fraction against an ideal Kynch flux balance with Richardson–Zaki hindered settling.
Ribbon Flowsheet → Dewatering → Thickeners
Model key DPSIM.Dewatering.IdealKynchThickener
Ports
| Port | Direction | Meaning |
|---|---|---|
| Feed | Input | Slurry with defined component densities. |
| Underflow | Output | All feed solids, with water at the specified solids volume fraction. |
| Overflow | Output | The remaining feed water. |
Configuration in DPSIM
- Connect Feed, Underflow and Overflow. Set the correct project component densities and confirm feed dry solids and water.
- Open the equipment editor. Enter settling area and target underflow concentration on a volume basis, then enter the settling velocity and exponent.
- Apply and run. Compare the applied flux and local flux limit at the requested target in the results view or Calculated Parameters. Check the concentration at the limiting point and the underflow flow.

Parameters and units
| Input | Units or options | Initial value or basis | Use |
|---|---|---|---|
| Settling area | m² | 100 | Enter positive active settling area. |
| Target underflow solids | % v/v | 25 | Enter a value strictly between 0 and 100 and at least as concentrated as the feed. |
| Unhindered settling velocity v₀ | m/h | 10 | Use a positive fitted velocity. |
| Richardson–Zaki exponent n | Dimensionless | 4.65 | Use a value at least 1, fitted over the slurry range of interest. |
Calculation and assumptions
Volume and water basis
Let Qₛ be the dry-solids volume rate, Qw water volume rate, A settling area and φᵤ the target fraction. Calculate solids volume by summing the component dry mass rates divided by their solids densities. The water-density assumption is 1 t/m³.
φ_feed = Qₛ / (Qₛ + Qw) Q_underflow = Qₛ / φᵤ Q_water,underflow = Q_underflow − Qₛ vᵤ = Q_underflow / A
Flux feasibility
At solids volume fraction φ, the Richardson–Zaki velocity is v₀(1 − φ)ⁿ. The total downward flux J combines gravity settling and underflow transport. DPSIM tests the minimum of J between φ_feed and φᵤ, including an admissible interior local minimum, against the applied solids flux Qₛ/A.
J(φ) = φ [v₀ (1 − φ)ⁿ + vᵤ] J_applied = Qₛ/A J_limit = min J(φ) over [φ_feed, φᵤ]
Balance and theoretical reference
If the imposed target passes the local flux check and the feed supplies enough water, all dry solids and the calculated water go to Underflow. The remaining water goes to Overflow. With no dry solids the water passes to Overflow. The separately reported ideal critical flux comes from the ideal settling curve and has a different basis than the target-specific limit.
Application
Use this for steady-state feasibility at a specified underflow target under ideal settling. Check calibration over the evaluated concentration range, especially where the slurry enters compression. Bed depth, torque and overflow clarity require separate methods.
Calculated results
| Result | Units or basis | How to interpret it |
|---|---|---|
| Applied solids volumetric flux and local limit | m³/m²/h | Compare this pair to establish target-specific hydraulic feasibility. |
| Feed and limiting solids concentration | % v/v | Confirm the model is evaluating the intended interval. |
| Underflow transport velocity and settling contribution | m/h and m³/m²/h | Distinguish the transport and gravity components of total flux. |
| Underflow slurry rate | m³/h | Compare with dry-solids volume divided by target volume fraction. |
| Ideal critical reference availability, flux and dry rate | Flag, m³/m²/h and t/h | Use as a theoretical reference when the ideal curve has an admissible critical state. |
Worked verification example
Use 24 dry t/h at solids density 3 t/m³ and 92 t/h water. Use A = 100 m², φᵤ = 25%, v₀ = 10 m/h and n = 4.65. The sample uses a combined feed volume of 100 m³/h.
| Check | Calculation or basis | Expected value |
|---|---|---|
| Dry-solids volume and feed fraction | 24/3 and 8/100 | 8 m³/h and 8% v/v |
| Underflow slurry and transport velocity | 8/0.25 and 32/100 | 32 m³/h and 0.32 m/h |
| Water to underflow and overflow | 32−8 and 92−24 | 24 and 68 t/h |
| Applied and limiting flux | 8/100, local minimum at 8% v/v | 0.0800 and 0.5685 m³/m²/h |

Diagnostics and calibration
| What you see | What to check |
|---|---|
| Target requires more water than the feed | Check the volume basis and enter an underflow target at least equal to feed solids by volume. |
| Applied solids flux exceeds capacity | Review area, settling data, feed density and target. Check that the selected slurry is represented by the calibrated curve. |
| Theoretical critical rate differs from the operating limit | Use the local limit at the entered underflow target to assess the operating case. |
