Summary

Check a specified underflow solids volume fraction against an ideal Kynch flux balance with Richardson–Zaki hindered settling.

Ribbon Flowsheet → Dewatering → Thickeners

Model key DPSIM.Dewatering.IdealKynchThickener

Ports

PortDirectionMeaning
FeedInputSlurry with defined component densities.
UnderflowOutputAll feed solids, with water at the specified solids volume fraction.
OverflowOutputThe remaining feed water.

Configuration in DPSIM

  1. Connect Feed, Underflow and Overflow. Set the correct project component densities and confirm feed dry solids and water.
  2. Open the equipment editor. Enter settling area and target underflow concentration on a volume basis, then enter the settling velocity and exponent.
  3. Apply and run. Compare the applied flux and local flux limit at the requested target in the results view or Calculated Parameters. Check the concentration at the limiting point and the underflow flow.
An editor example with a specified solids volume fraction and a comparison between applied flux and local limit.
An editor example with a specified solids volume fraction and a comparison between applied flux and local limit.

Parameters and units

InputUnits or optionsInitial value or basisUse
Settling aream²100Enter positive active settling area.
Target underflow solids% v/v25Enter a value strictly between 0 and 100 and at least as concentrated as the feed.
Unhindered settling velocity v₀m/h10Use a positive fitted velocity.
Richardson–Zaki exponent nDimensionless4.65Use a value at least 1, fitted over the slurry range of interest.

Calculation and assumptions

Volume and water basis

Let Qₛ be the dry-solids volume rate, Qw water volume rate, A settling area and φᵤ the target fraction. Calculate solids volume by summing the component dry mass rates divided by their solids densities. The water-density assumption is 1 t/m³.

φ_feed = Qₛ / (Qₛ + Qw)
Q_underflow = Qₛ / φᵤ
Q_water,underflow = Q_underflow − Qₛ     vᵤ = Q_underflow / A

Flux feasibility

At solids volume fraction φ, the Richardson–Zaki velocity is v₀(1 − φ)ⁿ. The total downward flux J combines gravity settling and underflow transport. DPSIM tests the minimum of J between φ_feed and φᵤ, including an admissible interior local minimum, against the applied solids flux Qₛ/A.

J(φ) = φ [v₀ (1 − φ)ⁿ + vᵤ]
J_applied = Qₛ/A     J_limit = min J(φ) over [φ_feed, φᵤ]

Balance and theoretical reference

If the imposed target passes the local flux check and the feed supplies enough water, all dry solids and the calculated water go to Underflow. The remaining water goes to Overflow. With no dry solids the water passes to Overflow. The separately reported ideal critical flux comes from the ideal settling curve and has a different basis than the target-specific limit.

Application

Use this for steady-state feasibility at a specified underflow target under ideal settling. Check calibration over the evaluated concentration range, especially where the slurry enters compression. Bed depth, torque and overflow clarity require separate methods.

Calculated results

ResultUnits or basisHow to interpret it
Applied solids volumetric flux and local limitm³/m²/hCompare this pair to establish target-specific hydraulic feasibility.
Feed and limiting solids concentration% v/vConfirm the model is evaluating the intended interval.
Underflow transport velocity and settling contributionm/h and m³/m²/hDistinguish the transport and gravity components of total flux.
Underflow slurry ratem³/hCompare with dry-solids volume divided by target volume fraction.
Ideal critical reference availability, flux and dry rateFlag, m³/m²/h and t/hUse as a theoretical reference when the ideal curve has an admissible critical state.

Worked verification example

Use 24 dry t/h at solids density 3 t/m³ and 92 t/h water. Use A = 100 m², φᵤ = 25%, v₀ = 10 m/h and n = 4.65. The sample uses a combined feed volume of 100 m³/h.

CheckCalculation or basisExpected value
Dry-solids volume and feed fraction24/3 and 8/1008 m³/h and 8% v/v
Underflow slurry and transport velocity8/0.25 and 32/10032 m³/h and 0.32 m/h
Water to underflow and overflow32−8 and 92−2424 and 68 t/h
Applied and limiting flux8/100, local minimum at 8% v/v0.0800 and 0.5685 m³/m²/h
The total flux, settling contribution and applied flux for the worked target. The point at 8% v/v limits this case.
The total flux, settling contribution and applied flux for the worked target. The point at 8% v/v limits this case.

Diagnostics and calibration

What you seeWhat to check
Target requires more water than the feedCheck the volume basis and enter an underflow target at least equal to feed solids by volume.
Applied solids flux exceeds capacityReview area, settling data, feed density and target. Check that the selected slurry is represented by the calibrated curve.
Theoretical critical rate differs from the operating limitUse the local limit at the entered underflow target to assess the operating case.

References