Summary
Estimate steady-state recovery to concentrate by combining true flotation and entrainment in a perfectly mixed compartment.
Ribbon Flowsheet → Concentration → Flotation
Model key DPSIM.Concentration.SavassiCompartmentCell
Ports
| Port | Direction | Meaning |
|---|---|---|
| Feed | Input | Slurry with dry component masses by size. |
| Concentrate | Output | Floated and entrained solids, plus the specified share of feed water. |
| Tailings | Output | Complementary solids and water. |
Configuration in DPSIM
- Define components and project size classes. Connect the slurry feed and both products before calibrating.
- Open the cell editor. Choose the residence-time basis and enter the water recovery separately from solids recovery.
- For each component, enter a scalar for all sizes or a list aligned to every project class from coarsest to pan. Enter froth recovery as percent and entrainment as a fraction.
- Apply and run. Compare the calculated flow rates and concentrate response against stream measurements and record the basis used for each fitted input.

Parameters and units
| Input | Units or options | Initial value or basis | Use |
|---|---|---|---|
| Residence time basis | Specified (0) or collection volume / feed flow (1) | 0 | Choose how the apparent mean residence time is obtained. |
| Specified apparent residence time | min | 5 | Use a positive calibrated value when selecting the specified basis. |
| Apparent collection-zone volume | m³ | 10 | Use positive apparent volume in the collection zone for the volume basis. |
| Water recovery to concentrate | % of feed water | 5 | Enter a value from 0 to below 100. The remaining water goes to tailings. |
| Apparent flotation rate k | min⁻¹, by component and class | 0 | Use a non-negative fitted rate. A scalar applies to all size classes. |
| Froth recovery Rf | %, by component and class | 100 | Enter values between 0 and 100 for attached solids transferred through the froth. |
| Degree of entrainment e | Fraction from 0 to 1, by component and class | 0 | Use a fractional value, for example 0.1 for 10%. |
Calculation and assumptions
Residence time
The apparent volume basis uses combined feed slurry flow, obtained from dry component volume and water volume. With zero feed, no throughflow occurs and the reported residence time is zero. On the specified basis the entered time is used.
τ = 60 Vc / Qf Vc in m³ Qf in m³/h τ in min
Flotation and entrainment by class
This implementation uses Savassi’s compartment equation for a perfectly mixed cell at steady state. Convert water recovery Rw and froth recovery Rf to fractions. For every component and size class, the flotation and entrainment contributions use a common denominator. Apply the recovery to feed dry mass in that class.
F = k × Rf × τ E = e × Rw / (1 − Rw) R_to concentrate = (F + E) / (1 + F + E) True flotation contribution = F / (1 + F + E) Entrainment contribution = E / (1 + F + E)
Balances and fitting
The model sends the remaining class dry mass to Tailings. Concentrate water equals feed water times Rw. For calibration, distinguish mineral components that share an elemental assay. At a single operating point, a recovery may constrain the product of k, Rf and τ without identifying each factor separately. Use independent measurements or multiple operating conditions to support the calibration.
Calculated results
| Result | Units or basis | How to interpret it |
|---|---|---|
| Dry-solids recovery to concentrate | % of feed dry solids | Sum the component and class contributions before comparing the bulk result. |
| Flotation and entrainment dry rates | t/h | Compare their sum with concentrate dry solids. |
| Concentrate water | t/h | Confirm the independently specified water split. |
| Apparent residence time and feed slurry flow used | min and m³/h | On the volume basis, verify that the selected volume and flow reproduce the reported time. |
| Concentrate response by size | % of feed component in class | Inspect the chosen component and the size mesh. A logarithmic plot omits the zero-aperture pan. |
Worked verification example
Use 100 dry t/h in one calibrated component and size class, 200 t/h water, τ = 5 min, k = 0.20 min⁻¹, froth recovery = 80%, entrainment degree = 0.1 and water recovery = 5%.
| Check | Calculation or basis | Expected value |
|---|---|---|
| Flotation and entrainment terms | 0.20 × 0.80 × 5 and 0.1 × 0.05/0.95 | 0.8000 and 0.005263 |
| Concentrate dry mass by mechanism | 100F/(1+F+E) and 100E/(1+F+E) | 44.315 and 0.292 t/h |
| Concentrate and tailings dry solids | Sum the two mechanisms, then take the complement | 44.606 and 55.394 t/h |
| Concentrate and tailings water | Apply the 5% water recovery | 10 and 190 t/h |
Diagnostics and calibration
| What you see | What to check |
|---|---|
| Calibration list rejected | Check the number of entries against the project size classes and include the pan in the order expected by the editor. |
| Entrained mass is unexpectedly high | Check the fraction entered for entrainment and the independently entered water recovery. |
| Recovery changes when feed flow changes | On the volume basis, changing Qf changes τ. Compare flow, time and calibration before interpreting the new case. |