Summary

Use Dobby’s general steel-wool drainage regression to partition slurry solids between magnetic and non-magnetic products.

Ribbon Flowsheet → Concentration → Magnetic Separation

Model key DPSIM.Concentration.WhimsDobbyGeneral

Ports

PortDirectionMeaning
FeedInputSlurry with a PSD and dry component mass by size.
MagneticOutputMagnetically captured and optionally entrained solids, with a specified share of feed water.
Non-magneticOutputThe remaining dry solids and water.

Configuration in DPSIM

  1. In Material, enter a measured profile for each populated component that uses capture. Choose None for a population with zero capture. When using a field curve, use measurements from the same sample and basis.
  2. In Magnetic Field & Matrix, enter the background induction and test loading. Identify whether its numerator represents all dry solids or the magnetic mineral mass in the feed.
  3. In Slurry & Capacity, select superficial velocity basis, then set water recovery and optional entrainment and capacity. Separate the gross frontal area used for superficial velocity from the free-area calculation.
  4. In Review, compare the draft preview with the last solver report. Apply, run the flowsheet and read Calculated Parameters before recording design inputs or results.

Parameters and units

InputUnits or optionsInitial value or basisUse
Component susceptibilitySI volumetric or m³/kg mass susceptibilityMeasured for each solid populationUse a constant or field curve. For mass susceptibility enter the measurement on a mass basis and confirm the component density used in the conversion.
Background induction BTMeasured away from the matrix wireEnter the field on the test basis. Use zero for a zero-field check.
Measured matrix gradientT/mOptional test recordRecord the test conditions. The correlation uses background induction.
Test matrix loading Lₘkg/kgCalibration test valueUse the entered dry feed mass or magnetic mineral mass per mass of matrix on the same basis as the experiment.
Parallel unitsPositive integer1Split feed slurry flow equally among identical operating units.
Superficial velocity sourceMeasured m/s or calculated from gross areaMeasured or flow / areaFor calculated velocity, enter gross active frontal area in m² per unit. Convert per-unit m³/h to m³/s first.
Free areaMeasured fraction or flat-plate geometryOptionalOpening velocity is a diagnostic. For flat parallel plates, use opening/(opening + thickness) if the geometry fits that assumption.
Open top class representative sizeµmMeasured representative diameterRequired for a populated open top class when a size-dependent calculation is active.
Feed water reporting to Magnetic% of water feedProcess inputSet the fraction independently from magnetic capture.
Conditional entrainment curveµm and % of uncaptured solidsOptional, zero when omittedProvide a curve covering all populated sizes.
Capacity curvem³/h per unit at stated loadingOptionalSelect the kg/kg matrix test loading basis or a measured retained-load basis in kg/m³ of matrix.
Calibration and extrapolationConfirmation and Allow flagged extrapolationReview against test envelopeConfirm the basis when magnetic capture is active. Review flagged points individually.

Calculation and assumptions

Scope of the fit

Dobby’s general steel-wool drainage regression uses 72 laboratory tests across hematite, ilmenite, sphalerite and chalcopyrite. Its standard error of estimate in that dataset was 9.7 percentage points. Equation 28 in the thesis and equation 9 in the paper document its basis.

Numerical units and field term

Use background induction B in T, superficial velocity u in m/s and representative particle diameter d in µm. Convert to H in kG and U in cm/s. Convert mass susceptibility to volumetric using component density, then use the numerical CGS susceptibility k. Mₘ is the wire magnetization term for the steel wool in the calibration.

H = 10B     U = 100u     k = χᵥ,SI / (4π × 10⁻⁴)
Mₘ = min(H, 10) kG
G = H Mₘ k^1.8 d^1.6 / (U^1.3 Lₘ^1.1)
Raw magnetic capture (%) = −58.9 + 38.3 log₁₀(G)

Class split and checks

Use the arithmetic midpoint for closed classes and half the finest aperture for the pan. At positive field and susceptibility, DPSIM bounds magnetic capture to 9–95%. A zero field or susceptibility produces zero magnetic capture. Conditional entrainment applies to uncaptured material, then the complementary dry solids go to Non-magnetic. The water split is specified independently.

Partition to Magnetic = Rₘ + (1 − Rₘ) E(d)
Capacity margin = tested admissible slurry flow − actual slurry flow per unit

Calibration envelope

The thesis envelope used by DPSIM is 0.04–1.30 T, 8.5–49 µm, 0.02–0.22 m/s, 0.17–2 kg/kg and k from 0.25 to 8. Compare your matrix, drainage procedure and susceptibility measurements with that basis. The fitted wire term saturates at 10 kG. At higher background field the product H Mₘ continues to change.

Calculated results

ResultUnits or basisHow to interpret it
Per-unit slurry flow and velocity basism³/h per unit and m/sCheck parallel unit count and the gross frontal area used. Opening velocity, where reported, is a separate diagnostic.
Raw capture, bounded capture and total partition% of each feed component and size classUse the class table in the last solver report. Total partition includes conditional entrainment.
Magnetic and non-magnetic productst/h dry solids and t/h waterConfirm separate dry-solids and water balances. Inspect grade and size distributions in the products.
Capacity check and signed marginm³/h per unitAdmissible flow minus actual flow. An overload reports a warning while the products still balance the full feed.
Extrapolation and untested capacityStatus by point or by capacity checkInspect flagged classes and review any capacity point marked Not checked.

Worked verification example

Use B = 0.09 T, u = 0.10 m/s, Lₘ = 0.67 kg/kg, k = 8 and d = 32 µm. For the balance, use 100 dry t/h of that class and 200 t/h water, conditional entrainment of 10% and 25% of feed water to Magnetic.

CheckCalculation or basisExpected value
Field and wire termH = 10 × 0.09, Mₘ = min(H, 10)0.9 and 0.9 kG
Logarithmic capture grouplog₁₀(G) on the published basis2.833605
Raw magnetic capture−58.9 + 38.3 × 2.83360549.6271%
Magnetic and entrained dry massApply entrainment to the uncaptured 50.3729 t/h49.6271 and 5.0373 t/h
Magnetic and non-magnetic dry massSum and complement54.6644 and 45.3356 t/h
Magnetic and non-magnetic water25% independent split50 and 150 t/h
Calculated raw capture across the overlapping size range used in the worked check. The general curve uses the wire magnetization term.
Calculated raw capture across the overlapping size range used in the worked check. The general curve uses the wire magnetization term.

Diagnostics and calibration

What you seeWhat to check
Missing susceptibility for a populated componentProvide a measured profile for that population or deliberately select None. Update the lookup if the component name changed.
Velocity or loading appears out of rangeConfirm superficial velocity and use the actual calibration numerator. Opening velocity and retained bed load answer different diagnostic questions.
Expected capture differs from reported partitionCompare raw capture, bounded capture, conditional entrainment and total partition for the same class.
Preview and solver show different valuesApply the settings and rerun. Verify that the solver feed and the draft feed snapshot describe the same operating condition.

References