Summary
Calculate wet high-intensity magnetic capture by particle size and component with the Dobby–Finch hematite and ilmenite drainage correlation.
Ribbon Flowsheet → Concentration → Magnetic Separation
Model key DPSIM.Concentration.WhimsDobbyFinch
Ports
| Port | Direction | Meaning |
|---|---|---|
| Feed | Input | Wet feed with component masses by particle size. |
| Magnetic | Output | Magnetically captured solids, optional entrainment and a specified fraction of water. |
| Non-magnetic | Output | Complementary solids and water. |
Configuration in DPSIM
- In Material, enter a measured profile for each populated component that uses capture. Choose None for a population with zero capture. When using a field curve, use measurements from the same sample and basis.
- In Magnetic Field & Matrix, enter the background induction and test loading. Identify whether its numerator represents all dry solids or the magnetic mineral mass in the feed.
- In Slurry & Capacity, select superficial velocity basis, then set water recovery and optional entrainment and capacity. Separate the gross frontal area used for superficial velocity from the free-area calculation.
- In Review, compare the draft preview with the last solver report. Apply, run the flowsheet and read Calculated Parameters before recording design inputs or results.

Parameters and units
| Input | Units or options | Initial value or basis | Use |
|---|---|---|---|
| Component susceptibility | SI volumetric or m³/kg mass susceptibility | Measured for each solid population | Use a constant or field curve. For mass susceptibility enter the measurement on a mass basis and confirm the component density used in the conversion. |
| Background induction B | T | Measured away from the matrix wire | Enter the field on the test basis. Use zero for a zero-field check. |
| Measured matrix gradient | T/m | Optional test record | Record the test conditions. The correlation uses background induction. |
| Test matrix loading Lₘ | kg/kg | Calibration test value | Use the entered dry feed mass or magnetic mineral mass per mass of matrix on the same basis as the experiment. |
| Parallel units | Positive integer | 1 | Split feed slurry flow equally among identical operating units. |
| Superficial velocity source | Measured m/s or calculated from gross area | Measured or flow / area | For calculated velocity, enter gross active frontal area in m² per unit. Convert per-unit m³/h to m³/s first. |
| Free area | Measured fraction or flat-plate geometry | Optional | Opening velocity is a diagnostic. For flat parallel plates, use opening/(opening + thickness) if the geometry fits that assumption. |
| Open top class representative size | µm | Measured representative diameter | Required for a populated open top class when a size-dependent calculation is active. |
| Feed water reporting to Magnetic | % of water feed | Process input | Set the fraction independently from magnetic capture. |
| Conditional entrainment curve | µm and % of uncaptured solids | Optional, zero when omitted | Provide a curve covering all populated sizes. |
| Capacity curve | m³/h per unit at stated loading | Optional | Select the kg/kg matrix test loading basis or a measured retained-load basis in kg/m³ of matrix. |
| Calibration and extrapolation | Confirmation and Allow flagged extrapolation | Review against test envelope | Confirm the basis when magnetic capture is active. Review flagged points individually. |
Calculation and assumptions
Scope of the fit
Use the hematite and ilmenite drainage regression in Dobby’s thesis equation 29 and the Dobby and Finch paper equation 10. The calculation runs for each populated component-size class.
Numerical units
H = 10B is field in kG from induction B in T. U = 100u is superficial velocity in cm/s from u in m/s. Use representative particle size d in µm and Lₘ in kg/kg. Convert volumetric SI susceptibility χᵥ to the numerical CGS basis k. For a mass susceptibility measurement, multiply by component density in kg/m³ before converting.
k = χᵥ,SI / (4π × 10⁻⁴) G = H² k^3.9 d^1.6 / (U^1.3 Lₘ^1.1) Raw magnetic capture (%) = −137.4 + 41.3 log₁₀(G)
Class partition
Closed bins use the arithmetic midpoint. The pan representative size is half the lowest physical aperture. For a positive field and positive susceptibility, the applied magnetic fraction Rₘ is bounded to 9–95%. At zero field or zero positive susceptibility its magnetic capture is zero. If E(d) is conditional entrainment as a fraction, apply it only to the mass left after magnetic capture.
Partition to Magnetic = Rₘ + (1 − Rₘ) E(d)
Calibration envelope
The fitted sample envelope is approximately 0.04–0.73 T, 8.5–48 µm, 0.02–0.22 m/s and 0.17–2 kg/kg. The nominal tested susceptibility values were 5.6–8.0 on the numerical CGS basis. Recorded matrix geometry, ore and drainage conditions matter even inside the numerical envelope. Use pilot or laboratory data that match the intended duty.
Calculated results
| Result | Units or basis | How to interpret it |
|---|---|---|
| Per-unit slurry flow and velocity basis | m³/h per unit and m/s | Check parallel unit count and the gross frontal area used. Opening velocity, where reported, is a separate diagnostic. |
| Raw capture, bounded capture and total partition | % of each feed component and size class | Use the class table in the last solver report. Total partition includes conditional entrainment. |
| Magnetic and non-magnetic products | t/h dry solids and t/h water | Confirm separate dry-solids and water balances. Inspect grade and size distributions in the products. |
| Capacity check and signed margin | m³/h per unit | Admissible flow minus actual flow. An overload reports a warning while the products still balance the full feed. |
| Extrapolation and untested capacity | Status by point or by capacity check | Inspect flagged classes and review any capacity point marked Not checked. |
Worked verification example
Use the published hematite calculation at B = 0.09 T, u = 0.10 m/s, Lₘ = 0.67 kg/kg and χᵥ,SI ≈ 0.010053 (k ≈ 8). For a synthetic balance, place 100 t/h dry solids entirely in the 32 µm class, supply 200 t/h water, choose 10% conditional entrainment and send 25% of the water to Magnetic.
| Check | Calculation or basis | Expected value |
|---|---|---|
| Magnetic capture at 18.7 µm | Before optional entrainment | 42.54% |
| Magnetic capture at 24.7 µm | Before optional entrainment | 50.52% |
| Magnetic capture at 32 µm | Before optional entrainment | 57.95% |
| Magnetic dry solids, synthetic 32 µm case | 100 × [0.57953 + (1 − 0.57953) × 0.10] | 62.16 t/h |
| Magnetic and non-magnetic water | 200 × 0.25 and its complement | 50 and 150 t/h |

Diagnostics and calibration
| What you see | What to check |
|---|---|
| Missing susceptibility for a populated component | Provide a measured profile for that population or deliberately select None. Update the lookup if the component name changed. |
| Velocity or loading appears out of range | Confirm superficial velocity and use the actual calibration numerator. Opening velocity and retained bed load answer different diagnostic questions. |
| Expected capture differs from reported partition | Compare raw capture, bounded capture, conditional entrainment and total partition for the same class. |
| Preview and solver show different values | Apply the settings and rerun. Verify that the solver feed and the draft feed snapshot describe the same operating condition. |
