How a drained product carries water
Three distinct measurements describe a dewatering unit. Dry solids capture is the share of feed dry solids in the retained product. Wet-basis moisture is water divided by the wet product mass. Capacity is the amount handled per unit time under defined operating conditions. Low moisture and high capture do not by themselves establish the capacity of a given filter or screen. For wet-basis moisture m, the water retained per unit dry solids is k = m/(1−m). On a dry basis, the same product moisture is reported as k. A cake reported at 18% wet-basis moisture carries 0.2195 t water per tonne of dry solids.
A filter for material balance
The DPSIM Basic Filter specifies dry solids recovery r to Cake and a cake solids fraction w*. Every component–size class uses the same r. Filtrate receives residual classes and cake retains the feed dry composition when both split streams have finite solids. The water requested at the target concentration is bounded by feed water.
The parameter called efficiency is capture of dry solids. It does not represent filtration energy, cycle utilization or equipment efficiency. The model uses the specified concentration at any throughput with adequate feed water, so capacity must be verified outside that split. Filtrate containing solids can become a recycle load or require further clarification. If r is near one, a small absolute error in r can produce a large relative error in filtrate solids.
Take 42 t/h dry solids and 58 t/h water. At r = 0.98 and cake solids 84% by mass, cake dry solids are 41.16 t/h, and retained water is 41.16 × 0.16/0.84 = 7.84 t/h. Filtrate contains 0.84 t/h solids and 50.16 t/h water, giving 1.647% solids. Wet cake is 49.00 t/h with 16% moisture. This result closes both balances exactly and can be used for a first estimate of filtrate recovery and wet cake conveyance.
Constant-pressure filtration as a capacity calculation
Separate filtration tests connect water removal to cycle time and area. Under fixed pressure drop Δp, constant filtrate viscosity μ and a constant specific cake resistance α, Darcy’s law gives the liquid flow through filter medium and cake in series. Let A be area, V filtrate volume, Rm medium resistance and c the deposited dry solids mass per filtrate volume. The cake resistance is αcV/A and increases with accumulated filtrate.
The second relation follows by integrating elapsed time with respect to V from zero. In SI, α has units m/kg, Rm units m⁻¹ and c units kg/m³. Fit t/V against V for constant pressure and representative slurry conditions. The intercept estimates μRm/(AΔp) and the slope estimates μαc/(2A²Δp). Wash, displacement, expression, air blow, loading, discharge and cloth cleaning can add time or water independently of the cake formation relation. An increase in Δp can compress the cake and raise its resistance, so use multiple pressure tests when scaling a compressible material. Cake moisture still requires measured or explicitly modeled drying and expression behavior. These capacity equations support engineering interpretation outside the Basic Filter split.
Consider A = 0.20 m², Rm = 10¹⁰ m⁻¹, α = 2 × 10¹¹ m/kg, c = 45 kg/m³, μ = 0.00125 Pa·s and Δp = 240 kPa. To produce 0.035 m³ of filtrate, medium resistance contributes 9.11 s, while cake resistance contributes 717.77 s. Formation takes 726.89 s. With another 360 s of preparation and discharge per cycle, dry capture is 45 × 0.035 = 1.575 kg per 1086.89 s, or 5.217 kg/h. This area-normalized rate of 26.08 kg/(m²·h) holds under the specified pressure and filter cycle. Doubling target filtrate volume at unchanged area nearly quadruples the cake-resistance time. Scaling by increasing area at the same filtrate volume per unit area preserves formation time in this idealization.
Vibrating-screen drainage
A dewatering screen separates water through openings as retained solids move along the deck. Residence is governed by along-deck solids motion. The active Ng Dewatering Screen uses empirical solid transport and a time-dependent approach to saturation moisture. Define angular frequency ω = 2πf/60 for vibration rate f in rpm. Use amplitude Aᵥ in metres, declination θ and vibration direction ψ in radians, and deck length L in metres.
Transport coefficients a, b₁ and b₂ and deck settings jointly determine solids velocity u. The equation requires positive passage time and an admissible vibration geometry. A change in angle can alter both normal motion and transport. With aperture s in millimetres, the drainage time exponent is q = q₁ + q₂(s−1). The predicted moisture is bounded by the feed moisture mfeed.
The measured size range and material basis of the fitted parameters matter. Defaults derived for coal should be fitted to other mineral feeds. Increasing screen length at unchanged u increases drainage time and approaches the saturation moisture. The moisture relation does not account for an arbitrary single particle on the deck, since its calibration summarizes bed drainage for a material and duty.
Classification and liquid split
In simple classification, eligible solids are the interval masses with mean size below the nominal screen aperture. Let Eₛ be their combined dry solids flow. In the coupled method, the recovery r of eligible solids to undersize equals the recovery of feed water to undersize. Their complement remains on deck with coarse solids. Setting k = m/(1−m), and assuming 0 < r < 1, gives an oversize water requirement k(S−rEₛ). The same water is W(1−r), so
The implementation guards dry or degenerate conditions and clips the valid recovery to [0,1]. In the Whiten modes the eligible mass comes from mass below aperture with within-class interpolation, and the panel passage probabilities are integrated over classes. The model can solve a common effective passage-trial rate from the water-based coupled recovery as its target, take a specified trial rate, or fit the rate to a specified eligible-solids recovery. The final oversize water always follows measured or calculated retained solids times k, capped by feed water. Thus an input target for eligible solids recovery is not automatically equal to the reported water recovery in these modes.
Worked screen case
Use f = 360 rpm, Aᵥ = 0.009 m, θ = 12°, ψ = 50°, L = 2.8 m and nominal aperture 0.75 mm. Set a = 1.87, b₁ = 1.44, b₂ = −2.52, q₁ = 0.33, q₂ = 0.081, msat = 0.08 and p = 0.21. Feed is 36 t/h dry solids and 54 t/h water, of which 15 t/h of solids belong to intervals eligible for passage under the simple mode.
| Intermediate or product | Calculated value |
|---|---|
| Angular frequency | 37.6991 rad/s |
| Normal acceleration ratio Gy | 0.97896 |
| Solids velocity and residence time | 0.16697 m/s and 16.7691 s |
| Drainage exponent q | 0.30975 |
| Oversize wet-basis moisture m | 0.16769 |
| Water per dry oversize mass k | 0.20147 |
| Coupled recovery r | 0.91701 |
| Oversize dry solids | 22.24490 t/h |
| Oversize water | 4.48165 t/h |
| Undersize dry solids | 13.75510 t/h |
| Undersize water | 49.51835 t/h |
The 91.70% recovery of eligible solids differs from the overall solids passage of 38.21%. The fraction r is also the water recovery to undersize in this simple case. The model reports a separate capacity estimate from feed F80, aperture and deck width. If F80 is 1.10 mm and width 1.8 m, capacity is (20 + 2.5 × 1.10)[1−exp(−4 × 0.75)] × 1.8 = 38.91 t/h of solids. The example is at 92.52% of that estimated load. This capacity indicator does not cap the routed feed. Use independent material tests to evaluate overload and screen efficiency.
Exercises and answers
- In the filter mass balance, increase target cake solids to 90% without changing capture. What are cake water, filtrate water and wet cake mass?
- A filter has an acceptable cake moisture but 0.4 t/h excess filtrate solids. Which Basic Filter parameter changes filtrate solids? What independent physical observations could justify that change?
- In the pressure-filtration example, estimate formation time at twice the area, handling the same filtrate volume. Hold other parameters fixed.
- In the screen case, find oversize moisture if transport slows so residence time doubles and mfeed still exceeds predicted moisture.
Answers
- Cake water is 41.16/9 = 4.5733 t/h, filtrate water is 53.4267 t/h and wet cake is 45.7333 t/h.
- Increase dry solids capture. Test filter-medium condition or pore structure, fine PSD of the feed and filtrate, and how much early-cycle filtrate escapes before cake formation.
- The medium term halves and the cake term quarters, giving 4.56 + 179.44 = 184.00 s.
- The predicted wet-basis moisture is 0.08 + 0.21(33.5382)⁻⁰·³⁰⁹⁷⁵ ≈ 0.1507. Product solids and final water follow from the new coupled balance.
Ng (1990), Dewatering Performance of Vibrating Screen, examined vibratory drainage and coal moisture. Teoh, Tan and Tien (2006) illustrate test-based analysis of the filtration resistance. A new procedure for determining specific filter cake resistance from filtration data. Active split and screen equations were checked against FilterBasic, SolidLiquidSeparationCalculations and NgDewateringScreen.