Chapter 25 · Water, Slurry Transport, and Dewatering

Process-water recovery and reuse

Recovery streams and actual makeup

Water recovered from a filter or thickener is available to the plant only if its destination can accept the flow and quality. A nominal recycle calculation begins with recoveries to the individual outlets, follows the real conveyance and clarification paths, and measures return flows against process demand. Water that leaves with wet cake remains a process loss even though the dry solids report to the desired destination. Suspended fines escaping to filtrate and dissolved species returning with reused water require separate balances.

For a steady process-water loop, take the control volume around the process and the water recovery operation. Internal recycle cancels. Let Wext denote external feed-associated water, M fresh makeup, Wprod product or tailings water loss, and Wreject the net purge or recovery reject leaving the boundary. In the absence of evaporation, other water additions and storage change, closure requires the following.

Wext + M = Wprod + Wreject.

For daily operations, distinguish unscheduled losses from controlled purge and count additive water such as wash water separately. At startup or shut-down, the difference between external input and output is the inventory change. A low tank level and a persistent fresh-water shortage can give the same reading at one instant, so the water ledger should use paired flow and inventory observations over time.

Worked thickener and filter loop

A solids-bearing process feed enters at 100 t/h dry solids and 40 t/h water. It requires 100 t/h water for the process duty. At an unchanged nominal solids flow, 60 t/h must be supplied by a blend of recovered process water and fresh makeup. Model dewatering using a Steady-State Thickener with 99.5% solids recovery to underflow at 60% mass solids, with no positive overflow solids target. Send the underflow to a Basic Filter using 99.0% dry solids capture and an 85% solids cake target.

StreamDry solids (t/h)Water (t/h)
Thickener feed100.000100.000
Thickener underflow99.50066.333
Thickener overflow0.50033.667
Filter cake98.50517.383
Filter filtrate0.99548.950
Combined water recovery feed1.49582.617

The overflow and filtrate provide more water than the point of use can accept. A disposal or storage destination is required even if all the needed water is recovered. Suppose an independent clarification operation and its associated flush reject 10% of that water. Usable water is 74.355 t/h. At a 60 t/h internal recycle, the planned and unplanned outgoing water outside the cake sum to 82.617 − 60 = 22.617 t/h. The cake and external reject water totals are 17.383 + 22.617 = 40 t/h. Process-associated feed water matches the outgoing external water, so fresh makeup is zero in this hydraulic operating point.

The combined 1.495 t/h secondary solids is a dry-solids load on clarification or another recovery circuit. The material balance here treats returned water as clarified with negligible suspended solids. If a clarification test measures significant bypass, add the returned solids to the process solids and recalculate thickener and filter duty. The cake and the external solids outlets must then account for the ore feed exactly after cancelling the internal solids recycle.

A dissolved-species constraint

Dissolved-species accumulation may set a stronger restriction than the hydraulic flow. For an illustrative conservative dissolved constituent, suppose the process adds 4 kg/h from the ore or chemical additions. All external water has negligible concentration. Assume complete mixing and equal dissolved concentrations in recovered liquor and the water carried in cake. There is no reaction or selective solute removal. The steady dissolved concentration c is found from the solute load divided by total water leaving the loop in m³/h, taking water density as 1 t/m³. With recycle flow R and process wet feed water fixed at 100 t/h, external water leaving is 100−R.

c = 4/(100−R) kg/m³.

At R = 60 t/h, c = 0.10 kg/m³ or 100 mg/L. If the process must stay at or below 80 mg/L, external water leaving must be at least 50 m³/h. The reuse flow is then at most 50 t/h. Fresh makeup is 10 t/h and the new external water discharge excluding cake is 32.617 t/h. Total external water output is 50 t/h, closing with 40 t/h associated feed water plus 10 t/h makeup. The calculated minimum makeup depends on how the constituent partitions and on external inputs. Clarification alone can improve suspended solids quality while leaving this dissolved-species constraint unchanged.

Audit the accounting across equipment

Represent each return by the water and residual solids actually routed downstream. The active Pulp Dilution Control calculates the water demand at unchanged dry solids, while Basic Filter and Steady-State Thickener determine which outlets carry the recovery candidate. A pump curve or launder calculation should evaluate predicted hydraulic duty at the returned flow, retaining the same material mass rates. Review local limits in addition to loop feasibility. A sump may only handle a short flow interruption before level or pump suction changes. A filter can satisfy its configured solids split while the real equipment requires more cycle area or operating time.

Compare among operating periods using both water intensity and production throughput. Fresh makeup of 10 t/h at 100 t/h dry ore is 0.10 m³/t under the chosen density. Water per wet tonne of cake answers a different question. Track which figure is used when plant feed moisture changes. Sampling should cover steady periods, changes in fresh-water quality and upset transitions. For proposed operating points above calibrated loading, use a feasible range of dewatering and clarification performance rather than a fixed recovery.

Exercises and answers

  1. In the worked loop, what is fresh makeup if the allowed conservative solute concentration is reduced to 65 mg/L, with no other changes?
  2. Estimate fresh makeup if the clarity and recovery operation can provide only 42 t/h usable liquor. Keep the 80 mg/L limit.
  3. With the filter recovery unchanged, reduce cake moisture to 12% wet basis. What cake water and candidate combined water are obtained?

Answers

  1. c = 0.065 kg/m³ requires at least 61.538 m³/h external discharge. Recycle is limited to 38.462 t/h and fresh makeup is 21.538 t/h.
  2. The hydraulic limit of 42 t/h binds before the solute limit of 50 t/h. Fresh makeup is 18 t/h and the solute concentration is 4/58 = 0.06897 kg/m³.
  3. Cake water is 98.505 × 0.12/0.88 = 13.4325 t/h. At unchanged feed and no other losses, combined thickener overflow and filtrate water is 86.5675 t/h. This shift moves 3.9514 t/h water from cake to the combined recovery stream.