Head, pressure and power
A pump supplies specific mechanical energy, commonly expressed as metres of head in the fluid being pumped. For slurry density ρ, gravitational acceleration g and pressure change Δp, the pressure head is Δp/(ρg). The same pressure requires more metres of head in water than in a denser slurry. For flow Q in m³/s and head H in metres, the power transmitted to the fluid is as follows.
Efficiencies enter as fractions. Use one density and one head basis in the energy calculation. If Q is recorded in m³/h, divide by 3600. A 5% hydraulic overflow or recirculating duty changes Q even when dry product tonnes per hour remain fixed.
For constant-diameter discharge and suction lines, static elevation, terminal pressure, and friction or fittings can be represented as terms in the system head. The Darcy–Weisbach expression for straight pipe with length L and diameter D in metres is as follows.
Here fD is the Darcy friction factor and ΣK sums local-loss coefficients in the same velocity basis. Inputs must match the intended implementation. An equivalent length for fittings can replace explicit K values when calibrated at the appropriate friction factor. Turbulent friction depends on Reynolds number and relative roughness. Lower diameter raises velocity and convergence toward the required design head can be steep. Very high velocity accelerates wear. Low velocity can let coarse solids settle and obstruct the line.
Three active pump calculations
| DPSIM model | What is specified | What is estimated |
|---|---|---|
| Slurry Pump Curve | Inlet flow, shutoff head, design flow, speed factor and efficiency | Available head, flow utilization and power on a simple speed-scaled curve |
| Standard Slurry Pump | Flow, pipe geometry, equivalent lengths, static duty, discharge pressure, surface conditions and slurry data | Required head, transport and deposition indicators, suction availability and power estimates |
| King Centrifugal Slurry Pump | Pump characteristic, correction ratios, system duty and either speed or feed flow | Required speed at supplied flow or hydraulic operating flow at known speed |
In Slurry Pump Curve, speed ratio s scales shutoff head with s² and nominal flow with s. Let x = Q/(sQdesign) using consistent volume units. Ignoring numerical floors, available head and efficiency follow these expressions.
The speed factor is relative to a base curve and the power follows from feed pulp density. The demand is given by the stream. This simple model can screen pump options and assess sensitivity around the reference condition. Set the actual operating range from manufacturer tests and check the available duty against the system requirement.
The Standard Slurry Pump estimates system head from a water-style empirical unit head loss. With Qapp in m³/s, C the Hazen–Williams coefficient and D the internal pipe diameter in metres, its unit loss is as follows.
Nominal pipe diameter in inches must be converted and reduced by twice the wall thickness, with all lengths in compatible units. For a line segment the model multiplies J by actual and equivalent lengths. It evaluates suction head as sump level minus suction loss. Discharge head includes static head, discharge loss and a pressure conversion using slurry density. The total slurry head is discharge head minus suction head. A legacy empirical head/efficiency ratio uses solids concentration, solids density and median size, and the reported water-basis head uses that correction. The source also reports a suction availability estimate from atmospheric and vapour heads with altitude and temperature corrections. The actual cavitation margin requires manufacturer suction-head data at the duty point and condition-specific allowance for aerated slurry. Report that margin separately from the transport velocity checks.
The Standard Slurry Pump source uses a metric power convention Qapp Hρ/(270η), with Qapp in m³/h and ρ in t/m³ for the slurry estimate. This is approximately metric horsepower. For kW, evaluate the SI power equation with the intended density and head basis or multiply metric horsepower by 0.7355. Retain the basis when comparing with a manufacturer's metric or mechanical horsepower figures.
King characteristic and the system operating point
For impeller diameter I, shaft speed N in revolutions per second, nᵦ identical parallel branches and nₛ stages in series in each branch, define reduced flow q = Q/(nᵦNI³). The active King characteristic uses three fitted coefficients A, B and C and a measured slurry-to-water head ratio rH.
When a flow is specified, the model solves a quadratic for N from Hp = Hrequired. Let X = Q/(nᵦ I³). The coefficients give the following equation.
When a speed is specified, the model searches the descending positive-head branch for the match between pump and system. Its friction uses laminar Darcy losses at low Reynolds number, a Haaland estimate in turbulent flow and an interpolation in transition. A calculated operating flow different from the connected feed is a hydraulic mismatch. The model passes the material stream through unchanged. Use the operating estimate to reconcile the proposed hydraulic duty with the circuit; treating it as an inserted flow would violate water and solids closure.
Fit the water characteristic before applying slurry corrections. Record the speed and impeller diameter for each reference point. Fit rH and slurry efficiency ratio from pump tests with a similar solids loading and size range. The corrected pump efficiency is water duty-point efficiency times the slurry efficiency ratio. A single measured duty point can anchor corrected head or efficiency but cannot identify all three water-curve coefficients. Multiple branches assume equal sharing. Unequal piping or wear can change branch flows.
Worked two-stage pump duty
A two-stage installation in one branch carries 240 m³/h at ρ = 1450 kg/m³ and μ = 0.0025 Pa·s. The line is 150 m long, 0.25 m in internal diameter, with roughness 0.12 mm. Static lift is 16 m and the terminal pressure requirement is 25 kPa. Use I = 0.36 m, A = 0.47, B = 0.18, C = 2.3 and rH = 0.89. Manufacturer water efficiency is 80%; slurry efficiency ratio is 0.87 and motor efficiency is 0.95. Use g ≈ 9.81 m/s² for hand calculation.
| Step | Result |
|---|---|
| Flow and line velocity | 0.066667 m³/s and 1.3581 m/s |
| Reynolds number and relative roughness | 196928 and 0.00048 |
| Haaland Darcy factor | 0.018557 |
| Friction head | 1.0467 m |
| Static plus terminal pressure head | 17.7575 m |
| Required total head | 18.8043 m |
With X = 0.066667/0.36³ = 1.4289 s⁻¹, BNX is the linear term in shaft speed. Solving the quadratic gives 41.096 revolutions per second or about 2466 rpm. Back-substitution gives q ≈ 0.034770 and h* ≈ 0.47348. The pump head calculates back to 18.804 m. Hydraulic power is 17.832 kW, shaft power is 25.621 kW and motor input is 26.969 kW. The calculated duty head is for both stages together. Each stage passes the same flow. If an identical train were added in parallel at the same total circuit flow, each branch would see half the flow under the equal-sharing assumption.
Open launder flow
A gravity launder uses water depth and slope as hydraulic degrees of freedom. The active Standard Open Launder evaluates a part-full circular cross-section. With depth y, diameter D and angle θ in radians, the wetted geometry is as follows.
The steady uniform Manning equation is Q = Aw Rh²ᐟ³ √J/nM, where nM is Manning roughness and J is bed slope in m/m. The model solves slope for a specified flow and depth using a coefficient rounded from the geometry. The calculated slope percent is 100J. It also reports a transport velocity indicator and a deposition estimate. Verify that fill depth is physically between zero and full and that required slope is available. For steady duty with adjustable depth, solve for the expected normal depth using reliable roughness and then check freeboard. An open circular section and a pressurized full pipe use different hydraulic conditions. For the active implementation, the effective froth factor is read after the apparent flow is calculated in each invocation, so a freshly changed setting should be reviewed after recalculation under the intended flow.
A circular launder of 0.60 m internal diameter carries 0.15 m³/s at depth 0.36 m. Set nM = 0.013. Then θ = 3.54431, Aw = 0.177130 m², Pw = 1.06329 m and Rh = 0.166587 m. Continuity gives v = 0.84683 m/s. Manning requires J = 0.001322, approximately 0.1322% or 1.322 mm vertical fall per metre. The result assumes the given apparent slurry volume and unobstructed wetted section. It does not establish that particles remain in suspension. Deposited solids reduce area and can change both the flow resistance and stable depth.
Exercises and answers
- For the worked launder, what slope is required if volume rises by 20% with depth and Manning coefficient fixed?
- A pump at 0.08 m³/s produces 22 m of slurry head at density 1300 kg/m³. Calculate shaft power at 72% efficiency.
- A pump moves slurry between reservoirs at unchanged elevation and terminal pressure. Ignoring static head and holding fD constant, by what factor does required friction head change at 1.2 times the original flow in the same pipe?
- What distinguishes increasing impeller speed from adding a series stage at fixed delivered flow?
Answers
- Slope scales with Q², giving 0.1322% × 1.2² = 0.1904%.
- Shaft power is 1300 × 9.81 × 0.08 × 22/(1000 × 0.72) = 31.17 kW.
- Friction head increases by 1.44 because velocity is proportional to Q. Actual fD can vary with Reynolds number.
- Raising speed changes both head scale and reduced flow. An identical stage in series adds head at common per-branch flow. It also changes installed equipment, power and operating conditions, even at the same final flow.
King (2002), Introduction to Practical Fluid Flow, describes a dimensionless pump characteristic. The active calculation sequence was checked against DPSIM’s StandardPump, StandardLaunder, SlurryPumpCurve and KingSlurryPump classes.